The keypad, see figure 2, can be used to set all parameters of the frequency regulators. The keypad must first be put in the ‘ALL USER menu’.
A: Function keys
B: Status
C: Bar graph
D: Function list 1
E: Function list 2
F: Parameter set
G: Code number
H: Sub-code number
I: Parameter contents with unit
Take the following steps to put the keypad in the ‘ALL USER menu’:
1 Connect the keypad (see figure 1, ).
2 Switch on the current of the frequency regulator (see figure 1, ); after a few seconds, the message shown in figure 1, will appear on the display.
3 Press (1<=>2) ; ‘1’ will appear on the display.
4 Press (=>); ‘USER’ will appear on the display.
5 Press (up); ‘ALL’ will appear on the display.
Press (<=>) ; the display will revert to the original situation.
The parameters can now be changed.
The second line of the display, see figure 2 arrow D, is important here.
Take the following steps to change the parameters:
At this moment ‘Disp’ is framed. Press => ; ‘Code’ is now framed.
Use (up) or (down) to go to the code (parameter) that is to be changed.
Press => at the desired code.
Some codes have a sub-code. If this is the case, then ‘Subcode’ will be framed.
Use (up) or (down) to go to the desired sub-code.
Press => at the desired sub-code.
‘Para’ is now framed.
‘Para’ is now framed.
Press (up) or (down) to enter the desired value.
Press (enter) to confirm the desired value.
Press (down) to decrease the value of Code ‘140’ to 0.00 Hz; the motor will stop running.
Press (up) to put the value of Code ‘1511’ back to ‘17’.